Ventilated facade system with aluminum composite panels
Application of HotRock thermal insulation boards made of stone wool in outdoor insulation structures with a ventilated gap for building walls
A metal frame with vertical bases is attached to the insulated wall using brackets. Between them, heat-insulating slabs made of stone wool are installed in the required number of layers. Fixing with a dowel ensures a tight fit of the material to the wall. During installation, it is important to provide a layer thickness of 5 cm for free air circulation. From above, the facade system is closed with a special plate on vertical guides.
As a heat-insulating layer in systems with a ventilated facade, it is recommended to use heat-insulating plates HotRock Vent Light, HotRock Vent Pro, HotRock Vent, HotRock Light. It is worth noting that they do not require additional devices for protection from moisture and wind.
In some cases, to reduce the load on the building structure and reduce the cost of construction, it is possible to use insulation in two layers, where plates can be used as an internal layer adjacent to the wall HotRock Light, HotRock Vent Light, with slabs as the outer layer HotRock Vent.
Ventilated facades have several advantages:
a protective screen (protective and decorative coating) made of sheet or piece materials protects the insulation from mechanical damage, precipitation, wind and solar radiation. Improves the appearance and facilitates the performance of work during the repair of thermal insulation of enclosing structures;
the ventilated gap eliminates the accumulation of moisture in the structure, which contributes to both increasing its heat-protective properties and durability, improving the temperature and humidity regime of premises;
the insulation design with a protective screen allows construction and repair work to be carried out all year round. At the same time, the degree of industrialization of construction and installation works on building insulation increases, and labor costs during construction and repair are reduced;
no pre-alignment of the load-bearing wall is required.
glue and other “wet” processes are excluded, since all structural elements are attached and connected mechanically:
long-term maintenance-free operation.
Construction
Load-bearing wall
Thermal insulation boards HotRock Vent Light, HotRock Vent Pro, HotRock Vent, HotRock Light
Interior decoration
Dowel poppet
Ventilated gap
Elements of the sub-banding structure (bracket, guide)
Facade panel